登录 | 注册    关注公众号  
微信公众号
搜索
 >  Kits>Nuclease >CRS-A031

resDetect™ GENIUS™ Nuclease ELISA Kit (Residue Testing)

For research use only.

产品描述(Product Details)

Assay TypeSandwich-ELISA
AnalyteNuclease
Format96T(8×12 strips)
Reactivity/
Regulatory StatusRUO
Sensitivity<25pg/mL
Standard Curve Range25 pg/mL-800 pg/mL
Assay Time3 hr 20 min
Suitable Sample TypeFor the quantitative determination the residue of nuclease in biologicals.
Sample volume100 uL

背景(Background)

resDetect™ GENIUS™ Nuclease ELISA Kit is based on ELISA sandwich method and designed for quantitative determination the residue of nuclease in biologicals. It contains Nuclease and a pair of antibodies against the eneyme, which are provided by ACROBiosystems. Results are obtained by four parameter logistic curve that were parallel to the standard curves obtained. The verification results indicate that this kit can be used for the quantitative determination of nuclease concentrations.

应用说明(Application)

resDetect™ GENIUS™ Nuclease ELISA Kit was developed for the detection and quantitative determination of nuclease in samples from downstream processing where nuclease is used as a process or purification aid.

The  limitation of detectable dose (LOD) of Cat. No. CRS-A016 was determined as 2.733 pg/mL.

It is for research use only.

重构方法(Reconstitution)

Please see Certificate of Analysis for details of reconstitution instruction and specific concentration.

存储(Storage)

1. Unopened kit should be stored at 2℃-8℃ upon receiving.

2. Find the expiration date on the outside packaging and do not use reagents past their expiration date.

3. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

组分(Materials Provided)

IDComponentsSize
CRS031-C01Pre-coated Anti-Nuclease Antibody Microplate1 plate(8×12 strips)
CRS031-C02Nuclease Standard5 μg
CRS031-C03Biotin-Anti-Nuclease Antibody20 μg
CRS031-C04Streptavidin-HRP50 μL
CRS031-C0510×Washing Buffer50 mL
CRS031-C062×Dilution Buffer50 mL
CRS031-C07Substrate Solution12 mL
CRS031-C08Stop Solution7 mL

原理(Assay Principles)

This assay kit employs a standard sandwich-ELISA format, providing a rapid detection of Nuclease. The kit consists of Pre-coated Anti-Nuclease Antibody Microplate and Nuclease Standard and Biotin-Anti-Nuclease Antibody and Streptavidin-HRP and buffers.

Your experiment will include 6 simple steps:

a) Bring all reagents to room temperature(20℃-25℃) before use.

b) Add your sample to the plate and take the Nuclease as standard. The samples and standard are diluted by Dilution Buffer.

c) Add the Biotin-Anti-Nuclease Antibody diluted by Dilution Buffer to the plate.

d) Wash the plate and add the Streptavidin-HRP diluted by Dilution Buffer to the plate.

e) Wash the plate and add TMB.

f) Stop the substrate reaction by adding diluted acid. Absorbance (OD) is calculated by the absorbance at 450 nm minus the absorbance at 630 nm to remove background disturbance before statistical analysis. The OD Value reflects the amount of bound protein.

 

典型数据-Typical Data Please refer to DS document for the assay protocol.

Nuclease TYPICAL DATA

For each experiment, a standard curve needs to be set for each micro-plate, and the specific OD value may vary depending on different laboratories, testers, or equipments. The following example data is for reference only.

Nuclease TYPICAL DATA

resDetect™ GENIUS™ Nuclease ELISA Kit (Residue Testing) (Cat. No. CRS-A031) can detect the nuclease in different culture supernatant with similar curve and sensitivity.

Nuclease TYPICAL DATA

resDetect™ GENIUS™ Nuclease ELISA Kit (Residue Testing) (Cat. No. CRS-A031) can detect the nuclease from different culture supernatant and was free from the matrix effects.

Nuclease TYPICAL DATA

resDetect™ GENIUS™ Nuclease ELISA Kit (Residue Testing) (Cat. No. CRS-A031) can detect the nuclease from different manufacturers, a nuclease levels differ from manufacturer to manufacturer.

 

验证(Validation)

批内差异(Intra-Assay Statistics)

Three samples of known concentration were tested ten times on one plate to assess intra-assay precision, Intra-Assay Precision CV≤15%.

Nuclease INTRA-ASSAY STATISTICS

批间差异(Inter-Assay Statistics)

Three samples of known concentration were tested in three separate assays to assess inter-assay precision, Inter-Assay Precision CV≤15%.

Nuclease INTER-ASSAY STATISTICS

回收率(Recovery)

Three Nuclease with different concentrations were tested to calculate the recovery rate.

Nuclease RECOVERY

 

背景(Background):Nuclease

Nucleases are enzymes that degrade nucleic acids, either DNA or RNA. It has been used for the preparation of nuclear extracts by digesting DNA and releasing nuclear proteins intimately associated with DNA. It has also been designed for removing RNA and DNA in biotechnological processing. Thus, the amount of residual nuclease in biological products should be detected and limited.

 

前沿进展

 
 
货号/价格
文档
联系电话:
+86 400-682-2521(全国)
010-53681107(北京)
021-50850665(上海)
运输方式
订单邮箱:
order.cn@acrobiosystems.com
技术支持邮箱:
tech.cn@acrobiosystems.com
前沿进展
点击查看详细

消息提示

请输入您的联系方式,再点击提交!

确定