登录 | 注册    关注公众号  
微信公众号
搜索
 >  Beads>TROP-2 >MBS-K028

Human TROP-2-coupled Magnetic Beads

热销产品推荐:The Magnetic Stand (Cat.No. MB-01 & Cat.No. MB-02) can be used in conjunction with Beads.

ItemsSize (2mg)Size(5mg X 2)
Particle size2 μm2 μm
Physical appearancePowder mixturePowder mixture
Amount of Coupled Protein≈1032 pmol (32.6 μg) TROP-2/mg beads≈1032 pmol (32.6 μg) TROP-2/mg beads
Binding Capacity>266 pmol (40μg) Anti-trop-2 antibody/mg beads>266 pmol (40μg) Anti-trop-2 antibody/mg beads
FormulationPBS, pH7.4, with 10% TrehalosePBS, pH7.4, with 10% Trehalose
Reconstitution2 mL sterile deionized water (1 mg beads/mL)5 mL sterile deionized water (1 mg beads/mL)

背景(Background)

The Human TROP-2-coupled Magnetic Beads is produced by coupling biotinylated TROP-2 heterodimer to streptavidin-conjugated magnetic beads. Because Streptavidin (SA) has an extraordinarily high affinity for biotin with a dissociation constant (Kd) on the order of 10-14 mol/L, the biotinylated protein can bind to the SA beads irreversibly. The pre-coupled beads are ready to use for capturing anti-TROP-2 antibody from your sample with high specificity.

表达区间及表达系统(Source)

Human TROP-2 Protein is expressed from human 293 cells (HEK293). It contains AA Gln 31 - Thr 274(Accession # P09758-1).

应用说明(Application)

This product is intended for immunocapture, biopanning and flow cytometry.

*The Isotype control (Cat. No. SMB-B01) is sold separately.

重构方法(Reconstitution)

See Certificate of Analysis (CoA) for detailed instruction.

存储(Storage)

Upon receipt, please store the beads at -20°C for 1 year in lyophilized state.

Please avoid more than 3 freeze-thaw cycles once reconstitution, immediate use after reconstitution is highly recommended.

原理(Assay Principles)

Antibody Purification: 1. Resuspend the lyophilized beads by adding the buffer of choice. 2. Add analyte to the suspension, mix and incubate to enable specific binding of the beads and the target protein. 3. Magnetize beads, remove supernatant, and wash unbound protein fractions to capture target protein-bound beads. 4. Wash, magnetize the beads and collect purified target protein for use in downstream applications.

The magnetic beads technology makes use of the easy and efficient collection of beads in magnetic field to facilitate antibody purification in a simple workflow of “bind-wash-elute”. In contrast to common separation techniques, this method does not require columns or centrifugation, and is therefore ideal in high-throughput applications.

制剂(Formulation)

Please contact us for detailed information.

Contact us for customized product form or formulation.

 

典型数据-Typical Data

TROP-2 TYPICAL DATA

Immobilized 32.6 μg TROP-2/1 mg beads can bind Anti-TROP-2 mAb with an EC50 of 0.8505 μg/mL.

Protocol

TROP-2 TYPICAL DATA

Accelerated stability test. After placing the lyophilized beads at 37°C for 7 days, binding activity between the Human TROP-2-coupled Magnetic Beads (Cat.No. MBS-K028) and anti-trop-2 mAb showed little deviation from the unaccelerated sample (%RSD<10%). Data were measured on day 0, 3, 7 respectively.

Protocol

TROP-2 TYPICAL DATA

Freeze-thaw stability test. After different freeze-thaw cycles, binding activity between the Human TROP-2-coupled Magnetic Beads (Cat.No. MBS-K028) and anti-trop-2 mAb showed little deviation from the unfreeze-thaw sample (%RSD<10%). Three freeze-thaw cycles were performed.

Protocol

 

前沿进展

 
 
货号/价格
文档
联系电话:
+86 400-682-2521(全国)
010-53681107(北京)
021-50850665(上海)
运输方式
订单邮箱:
order.cn@acrobiosystems.com
技术支持邮箱:
tech.cn@acrobiosystems.com
TROP-2靶点信息
英文全称:Tumor-associated calcium signal transducer 2
中文全称:肿瘤相关钙信号传感器2
种类:Homo sapiens
上市药物数量:1详情
临床药物数量:19详情
最高研发阶段:批准上市
查看更多信息
前沿进展
点击查看详细

消息提示

请输入您的联系方式,再点击提交!

确定